Skip to main content
Labshock✕
LoginStart Free

Learning in Labshock

OT security curriculum

Explore industrial systems, offensive techniques and defensive work, then connect them in an investigation.

World of Labshock skill tree with Industrial, Offensive and Defensive learning paths.
OT incident response

Industrial

Understand the equipment and the process it controls.

  • PLC, RTU and I/O
  • HMI and SCADA
  • Sensors and actuators
  • Industrial networks
  • Industrial protocols
  • Control logic and scan cycle
  • Signals and feedback
  • Interlocks and control modes

Offense

Understand access paths, possible actions and their effects.

  • Reconnaissance and discovery
  • Network scanning
  • Service enumeration
  • Initial access and credentials
  • Privilege escalation
  • Lateral movement and pivoting
  • Protocol manipulation
  • Controller and HMI changes

Defense

Find evidence, investigate activity and plan a response.

  • Asset identification
  • Traffic analysis
  • Segmentation and access control
  • Logging and data quality
  • SIEM search and correlation
  • Detection engineering
  • Alert triage and investigation
  • Containment and recovery

Where the paths meet

Advanced security

Bring process knowledge, attacker behavior and evidence together to investigate an incident and choose a response.

  • Threat hunting
  • Incident investigation
  • Containment decisions
  • Recovery validation

What you can study

Explore the skill library

Open a skill to see its practical purpose and related learning material.

IFNIndustrial Foundations

Identify the main OT devices and explain what each one does.

Related guides and labs

  • GuideWhat we are protecting

    Loginward · Level 8

  • GuidePLC

    Signalspire · Level 11

  • LabLAB PLC login

    Signalspire · Level 11

  • GuideHMI

    Signalspire · Level 12

  • LabLAB HMI Login

    Signalspire · Level 12

  • GuidePLC & Field

    Signalspire · Level 13

PAWProcess Awareness

Check whether a command produced the expected physical result.

Related guides and labs

  • GuideWhat we are protecting

    Loginward · Level 8

  • GuidePLC & Field

    Signalspire · Level 13

  • GuideBasics

    Signalspire · Level 16

  • GuideProcess Truth

    Logicveil · Level 21

  • GuideThe Control Loop and Scan Cycle

    Logicveil · Level 21

  • GuideControl Authority

    Logicveil · Level 22

PUAPurdue Architecture

Place devices by their function and explain where network boundaries are needed.

Related guides and labs

  • GuideWhat we are protecting

    Loginward · Level 8

  • LabLAB Map the Network

    Signalspire · Level 13

  • GuideL2 & HMI

    Signalspire · Level 14

  • GuideL3 & SCADA

    Netfields · Level 22

  • GuideOT DMZ and the Transfer Service

    Firegate · Level 35

INWIndustrial Networking

Trace an OT communication path through switches, routers and security boundaries.

Related guides and labs

  • LabLAB Map the Network

    Signalspire · Level 13

  • GuideL2 & HMI

    Signalspire · Level 14

  • GuideL3 & SCADA

    Netfields · Level 22

  • GuideL2

    Netfields · Level 23

  • GuideL3

    Netfields · Level 24

  • GuideNetwork & Remote Access

    Firegate · Level 35

  • GuidePROFINET Real Time Model

    Blackcoil · Level 51 · In preparation

  • LabLAB Capture PROFINET and DCP

    Blackcoil · Level 51 · In preparation

PLFPLC Fundamentals

Read a PLC’s hardware, I/O, memory and timing information.

Related guides and labs

  • GuidePLC

    Signalspire · Level 11

  • LabLAB PLC login

    Signalspire · Level 11

  • GuideBasics

    Signalspire · Level 16

  • GuideThe Control Loop and Scan Cycle

    Logicveil · Level 21

  • GuideAutomation Anatomy

    Thunderwatch · Level 30

  • GuidePLC Thinking Model

    Thunderwatch · Level 31

  • GuidePLC Memory and Variables

    Thunderwatch · Level 35

  • LabLAB Build Variable Map

    Thunderwatch · Level 35

  • GuideTimer and Counter Logic

    Thunderwatch · Level 36

  • LabLAB Boiler Timer and Counter Logic

    Thunderwatch · Level 36

  • GuideFunction Block Architecture

    Thunderwatch · Level 37

  • LabLAB Heating Controller in ST

    Thunderwatch · Level 37

AIVAsset Inventory

Keep an engineering asset list and resolve differences with observations.

Related guides and labs

  • GuideWhat we are protecting

    Loginward · Level 8

  • LabLAB Map the Network

    Signalspire · Level 13

  • GuideL3 & SCADA

    Netfields · Level 22

  • GuideOT Asset Inventory

    Netfields · Level 25

  • LabLAB Map the Zones and Assets

    Firegate · Level 35

SAHSCADA & HMI

Check HMI values, command bindings and alarms.

Related guides and labs

  • GuideHMI

    Signalspire · Level 12

  • LabLAB HMI Login

    Signalspire · Level 12

  • LabLAB Interface & Objects

    Logicveil · Level 22

  • LabLAB Tags & Properties

    Logicveil · Level 23

  • LabLAB Alarms

    Logicveil · Level 24

EWSEngineering Workstation

Compare saved, installed and backed-up controller projects.

Related guides and labs

  • GuideHMI

    Signalspire · Level 12

  • GuideControl & Application

    Logicveil · Level 26

  • GuideAutomation Anatomy

    Thunderwatch · Level 30

  • GuideProgram Organization Units

    Thunderwatch · Level 38

  • GuideRuntime Deployment and Live Debugging

    Thunderwatch · Level 39

  • LabLAB Online Changes and Live Memory

    Thunderwatch · Level 39

CLGControl Logic

Predict simple PLC logic using small input-and-output traces.

Related guides and labs

  • GuideThe Control Loop and Scan Cycle

    Logicveil · Level 21

  • GuideIndustrial Data Flow

    Thunderwatch · Level 32

  • LabLAB Trace the Flow

    Thunderwatch · Level 32

  • GuideLadder Logic Foundations

    Thunderwatch · Level 33

  • LabLAB First PLC Program

    Thunderwatch · Level 33

  • GuideStructured Text Execution Model

    Thunderwatch · Level 34

  • LabLAB ST Program

    Thunderwatch · Level 34

  • GuidePLC Memory and Variables

    Thunderwatch · Level 35

  • LabLAB Build Variable Map

    Thunderwatch · Level 35

  • GuideTimer and Counter Logic

    Thunderwatch · Level 36

  • LabLAB Boiler Timer and Counter Logic

    Thunderwatch · Level 36

  • GuideFunction Block Architecture

    Thunderwatch · Level 37

  • LabLAB Heating Controller in ST

    Thunderwatch · Level 37

PLPIndustrial Protocols

Recognize industrial protocol operations and point addresses in captured traffic.

Related guides and labs

  • GuideModbus 1 - Theory & Memory

    Netfields · Level 20

  • GuideModbus 2 - Network Traffic

    Netfields · Level 21

  • GuideS7 part 1 - Origins

    Logicveil · Level 23

  • GuideS7 part 2 - In Action

    Logicveil · Level 24

  • GuideS7 part 3 - Packets

    Logicveil · Level 25

  • GuideIEC104 Telecontrol Model

    Firegate · Level 31

  • LabLAB Capture IEC104 Traffic

    Firegate · Level 31

  • GuideIEC104 Points and Commands

    Firegate · Level 32

  • LabLAB Operate IEC104 Points

    Firegate · Level 32

  • GuideDNP3 Master-Outstation Model

    Firegate · Level 33

  • LabLAB Poll a DNP3 Outstation

    Firegate · Level 33

  • GuideDNP3 Objects, Events, and Controls

    Firegate · Level 34

  • LabLAB Control DNP3 Points

    Firegate · Level 34

  • GuidePROFINET Real Time Model

    Blackcoil · Level 51 · In preparation

  • LabLAB Capture PROFINET and DCP

    Blackcoil · Level 51 · In preparation

INDIndustrial Data

Check a tag’s identity, units, quality and age before using its value.

Related guides and labs

  • GuideMQTT Telemetry Model

    Logfall · Level 41

  • LabLAB Capture MQTT Traffic

    Logfall · Level 41

  • GuideOPC UA Information Model

    Mindrock · Level 41

  • LabLAB Browse the OPC UA Address Space

    Mindrock · Level 41

SFISafety & Interlocks

Distinguish start conditions, protective actions and their dependencies.

Related guides and labs

  • GuideSafety Before Security

    Netfields · Level 20

  • GuideControl Authority

    Logicveil · Level 22

  • GuideNuclear Balance of Plant and Defense in Depth

    Blackcoil · Level 50 · In preparation

PCNProcess Control

Explain a control loop using its measurement, target and output.

Related guides and labs

  • GuidePLC & Field

    Signalspire · Level 13

  • GuideProcess Truth

    Logicveil · Level 21

  • GuideThe Control Loop and Scan Cycle

    Logicveil · Level 21

  • GuideIndustrial Data Flow

    Thunderwatch · Level 32

  • GuideChemical Process and the Batch Estate

    Mindrock · Level 40

  • LabLAB Map the Brackwater Plant

    Mindrock · Level 40

ITBIndustrial Troubleshooting

Narrow an OT fault by comparing evidence from each system layer.

Related guides and labs

  • LabLab Logs

    Loginward · Level 6

  • LabLAB Visibility & Logs

    Signalspire · Level 18

  • GuideOT vs IT

    Logicveil · Level 20

  • LabLAB Alarms

    Logicveil · Level 24

  • GuideL3

    Netfields · Level 24

  • GuideRuntime Deployment and Live Debugging

    Thunderwatch · Level 39

PIGPlant Integration

Trace one process value across systems without losing its meaning.

Related guides and labs

  • LabLAB Map the Network

    Signalspire · Level 13

  • GuideICS Building Blocks

    Logicveil · Level 20

  • GuideGrid Layout and the Electroshock Substation

    Firegate · Level 30

  • LabLAB Map the Electroshock Yard

    Firegate · Level 30

  • LabLAB Walk the Electroshock Substation

    Firegate · Level 39

  • LabLAB Map the Coldwater Station

    Blackcoil · Level 50 · In preparation

  • LabLAB Map the Helios Array

    Ethergrid · Level 50 · In preparation

  • GuideIEC 61850 GOOSE on the Station Bus

    Ethergrid · Level 51 · In preparation

  • LabLAB Capture GOOSE Traffic

    Ethergrid · Level 51 · In preparation

IENIndustrial Engineer

Summarize a plant issue with its signal path, dependencies and verification evidence.

Advanced material in preparation

Related guides and labs

  • GuideRecovery and Restore to Known Good

    Blackcoil · Level 59 · In preparation

  • LabLAB Restore the PLC and SCADA

    Blackcoil · Level 59 · In preparation

  • GuideRecover and Report

    Shocklands · Level 63 · In preparation

  • LabLAB Recover Reconstruct and Report

    Shocklands · Level 63 · In preparation

  • GuideBoth Chairs Capstone

    Shocklands · Level 64 · In preparation

  • LabLAB Run the Shocklands Incident

    Shocklands · Level 64 · In preparation

References behind this branch

Use the public outlines to find topics to study. Labshock connects selected topics to its own industrial guides and practice.

One incident, three perspectives

Someone changed the PLC logic

Follow the same event through each part of the curriculum.

Industrial

Which equipment does this logic control? Which feedback and process measurements show the effect?

Offense

How was the controller reached? Which account and access path allowed the change?

Defense

Where is the evidence? What else happened, and which response accounts for process dependencies?

Study with your AI agent

Work through one topic

Ask for an explanation, a concrete example and original documentation. Use a lab to check what you understood.

Help me study [topic] for OT incident response. Explain the prerequisites and main concepts, give one PLC or HMI example, and link to free primary sources. Suggest a safe lab exercise and ask questions to check my understanding.

Learning routes in World

Find your next step

These are the guide level bands. Parallel zones explore different systems at the same stage.

  1. Levels 1–8

    Start with the environment

    Bring a lab online, use its interfaces and find the first sources of evidence.

    Loginward8 guides and labs
  2. Levels 10–18

    Understand OT systems

    Meet PLCs and HMI, trace the process and observe industrial communication.

    Signalspire17 guides and labs
  3. Levels 20–29

    Work with protocols and control

    Explore Modbus and S7, control authority, traffic analysis and monitoring.

    Netfields21 guides and labsLogicveil19 guides and labs
  4. Levels 30–39

    Build logic and check boundaries

    Study PLC programming, IEC 104 and DNP3, remote access, DMZs and firewall rules.

    Thunderwatch18 guides and labsFiregate24 guides and labs
  5. Levels 40–49

    Investigate and build detections

    Follow MQTT and OPC UA environments into Splunk, Wazuh, Suricata, detection rules and triage.

    Logfall25 guides and labsMindrock24 guides and labs

Access to guides and labs depends on your plan, progress and the current World catalog. A guide level describes its place in the curriculum; completing reading alone does not demonstrate a practical skill.

Choose a topic and try it in a lab

Begin in World or explore the industrial environments behind the learning routes.